Chart E: Sensor Test
Wiring Diagram:
- If diagnostic trouble codes 10, 13, and 15 are set, check YEL (61) wiring for an open. Check HVAC Programmer Connector (terminal D6-sensor return) for proper terminal contact.
- If diagnostic trouble codes 13 and 15 are set, check YEL (61) wiring between splice S296 and S231 for an open (see schematic); check in-line Connector C200 (terminal H6) for proper terminal contact. Ignition Switch: RUN