Blower Motor: Service and Repair
Fig. 13 Blower Motor Case Attaching Screw Locations.:
Fig. 14 Blower Motor & Case Assembly.:
1. Disconnect battery ground cable.
2. Proceed as follows:
a. Depress glove compartment stopper, then pull rearward.
b. Remove glove compartment to instrument panel attaching screws, remove glove compartment.
c. Remove ECM three attaching screws, disconnect electrical connectors, then remove ECM.
3. Disconnect blower motor and blower resistor electrical connectors.
4. Disconnect fresh air control cable from blower motor housing.
5. Remove three blower motor housing attaching bolt, then remove blower motor housing, Fig. 13 .
6. Remove air hose, then remove three attaching screws and separate blower motor from housing, Fig. 14 .
7. Reverse procedure to install.