Operation CHARM: Car repair manuals for everyone.

Stop Lamps

Battery positive voltage (B+) is supplied at all times from the IF fuse block BRK/HZRD LPS Fuse 613 via CKT 140 (ORN) to the stoplamp/BTSI switch. When the brake pedal is pressed, battery positive voltage (B+) is applied through the stoplamp/BTSI switch via CKT 20 (LT BLU) to the stop lamps causing the stop lamps to light.