Operation CHARM: Car repair manuals for everyone.

Positive Crankcase Ventilation: Service and Repair






REMOVAL PROCEDURE
1. Remove the injector sight shield from the fuel rail and intake. Refer to Engine Cover Replacement Service and Repair.
2. Remove the MAP sensor (1).
3. Use a 16 mm socket to press the access cover (2) down and rotate 1/4 turn counterclockwise.
4. Remove the access cover.
5. Remove the PCV valve (3) and the O-ring (4) from the intake manifold.

INSTALLATION PROCEDURE
1. Install the crankcase ventilation valve (3); replace the O-ring (4) if necessary.
2. Install the access cover (2).
3. Install the MAP sensor (1).
4. Install the sight shield. Refer to Engine Cover Replacement Service and Repair.