Express Down Feature
When the LF Window Switch is pressed to first detent in the DN position, the express down circuit within the Master Window Switch engages and applies voltage to the 165 circuit. The left front window moves to the fully open position. When the left front window mechanical its mechanical limit, the current draw to this motor increases significantly. The express down circuits in the Master Window Switch senses this current draw and removes power to the Window Motor