High Pressure Relief Valve Description
The compressor is equipped with a pressure relief valve, which acts as a mechanical safety device. Under certain conditions,
refrigerant pressure on the compressor discharge side may exceed the designed operating level. In order to prevent system damage, the valve is designed to open automatically at approximately
3171-4137 kPa (461-5 Hg psi). This will vent the refrigerant to the atmosphere. Fix any condition that causes this valve to open incorrectly. Replace the
refrigerant oil and the refrigerant as needed.