IAT Sensor
The scan tool range is
40°C to +151°C (-40°F to +304°F). The
PCM converts the resistance of the
intake air temperature sensor to degrees. The PCM uses the Intake Air Temperature
(IAT) to adjust fuel delivery and spark timing according to incoming air density. IAT is also compared to ECT at start-up to identify cold starts for the
HO2S heater and the
EVAP diagnostics.