IAT Sensor
The scan tool range is
-40° to +151°C (-40° to +304°F). The
PCM converts the resistance of the
intake air temperature sensor to degrees. The PCM uses Intake Air Temperature
(IAT) in order to adjust fuel delivery and spark timing according to incoming air density. IAT is also compared to ECT at start-up to identify cold starts for the
HO2S heater and the
EVAP diagnostics.