Convertible Top Control Module: Service and Repair
Folding Top Control Module Replacement
Removal Procedure
Caution: Refer to Eye Protection Caution.
Caution: Refer to Folding Top Hydraulic Pressure Caution.
Caution: Refer to Servicing Electrical Components Caution.
1. Place the folding top in the up position.
2. Open the rear compartment.
3. Remove the right side compartment trim.
4. Remove the 2 nuts that attach the control module to the pump bracket.
5. Disconnect the electrical connectors from the control module.
6. Remove the control module from the pump bracket.
Installation Procedure
1. Position the control module to the pump bracket.
2. Connect the electrical connectors to the control module.
Notice: Refer to Fastener Notice.
3. Install the 2 nuts that attach the control module to the pump bracket.
Tighten the nuts to 18 N.m (13 lb ft).
4. Install the side compartment trim.
5. Close the rear compartment.
6. Inspect the folding top for proper operation.