High Pressure Safety Valve HVAC: Service and Repair
Compressor Pressure Relief Valve Replacement
Tools Required
J39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
Important: Cap or tape the open A/C components immediately to prevent system contamination.
2. Remove the air conditioning compressor.
3. Remove the high pressure relief valve.
Installation Procedure
1. Remove the cap or tape from the A/C compressor.
Notice: Refer to Fastener Notice.
2. Install the high pressure relief valve.
Tighten the valve to 8 N.m (70 lb in).
3. Install the air conditioning compressor.
4. Evacuate and recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
5. Leak test the fittings of the component using J39400-A.