P0010
DTC P0010
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
DTC Descriptors
DTC P0010
- Intake Camshaft Position (CMP) Actuator Solenoid Control Circuit
Diagnostic Fault Information
Circuit/System Description
The CMP actuator solenoid enables the powertrain control module (PCM) to change the intake camshaft timing while the engine is running. The CMP actuator solenoid contains a spool valve that controls the advance of the camshaft. The CMP actuator solenoid valve is controlled by a pulse width modulated (PWM) signal from the PCM. The CMP sensor monitors the camshaft position or the camshaft angle, and compares that position or phase to the crankshaft position (CKP) sensor signal. The PCM determines whether the camshaft angle is correct by comparing the actual camshaft position to the target camshaft position. By continuously analyzing the input of the CMP sensor and the CKP sensor the PCM can detect a fault in the CMP actuator system.
Conditions for Running the DTC
* The ignition is ON.
* DTC P0010 runs continuously once the above condition is met.
Conditions for Setting the DTC
The PCM detects an open or a short in the CMP actuator solenoid control circuit.
Action Taken When the DTC Sets
DTC P0010 is a type A DTC.
Conditions for Clearing the DTC
DTC P0010 is a type A DTC.
Diagnostic Aids
Scan tool output control of the CMP actuator solenoid valve is disabled as soon as DTC P0010 is detected. Because DTC P0010 sets immediately when an open or short is present in the solenoid control circuit, the circuit cannot be disconnected and diagnosed using the scan tool.
Reference Information
Schematic Reference
Engine Controls Schematics (Electrical Diagrams)
Connector End View Reference
* Powertrain Control Module Connector End Views (Powertrain Control Module Connector End Views)
* Engine Controls Connector End Views (Engine Controls Connector End Views)
Description and Operation
Camshaft Actuator System Description (Camshaft Actuator System Description)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions (Diagnostic Trouble Code Descriptions)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Verification
Important: All CMP actuator system DTCs must be cleared before the CMP actuator solenoid scan tool output control is enabled.
1. Engine running at normal operating temperature, command the CMP actuator solenoid ON with the scan tool. The engine should run rough or stall.
2. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the camshaft position (CMP) actuator solenoid.
2. Ignition OFF, test for less than 5 ohms between the CMP low control circuit terminal 2 and ground.
• If greater than the specified range, test the CMP low control circuit for an open/high resistance. If the circuit tests normal, replace the PCM.
3. Engine running, connect the CMP actuator solenoid to B+ and ground with a pair of 10A fused jumper wires. Verify the engine runs rough or stalls.
• If the engine does not run rough or stall, test or replace the CMP actuator solenoid.
4. Test the solenoid high control circuit for a short or an open/high resistance.
• If the circuit tests normal, replace the PCM.
Component Testing
1. Ignition OFF, disconnect the harness connector of the CMP actuator solenoid.
2. Test for 6.9-7.9 ohms at 20°C (68°F) between the actuator solenoid terminals.
• If not within the specified range, replace the CMP actuator solenoid.
3. Test for infinite resistance between each terminal of the CMP actuator solenoid and the CMP actuator solenoid housing.
• If not the specified value, replace the CMP actuator solenoid valve.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Camshaft Position Actuator Solenoid Valve Replacement (Camshaft Position Actuator Solenoid Valve Replacement)
* Control Module References (Programming and Relearning) for engine control module replacement, setup, and programming