Mode 2
Mode 2
The following PID's are supported in Mode 2:
$00 Supported PID's
The PID's supported in this mode are displayed in a 4- byte word.
Data A
Data B
Data C
Data D
NOTE:
- If there is a fault not all supported PID's are stored in the memory, but only 6.
- The Data A and B bytes indicate that PID's 02, 03, 04, 05, 06, 07, 08, 09, OC and OD are supported. From these supported PID's, the 6 most meaningful ones are stored for one fault.
$02 Diagnostic Trouble Code
The Diagnostic Trouble Code which caused the storage of freeze frame data is displayed.
$03 Status of injection system
Mode 42Pid$03 Adr$17
Data A Data B
00001000 00001000
Data A - Status of bank 1
Data B - Status of bank 2
Bit 0 - Open-loop control, the conditions for closed- loop oxygen sensing have not yet been satisfied.
Bit 1 - Closed-loop control, the signal from the oxygen sensor is used to control injection.
Bit 2 - Open-loop control through conditions such as full load, etc.
Bit 3 - Open-loop control through faults in the system.
Bit 4 - Closed-loop control, but faults from at least one oxygen sensor.
Bits 5 to 7 not used.
NOTE: Only one bit at a time can be set to 1 to indicate the status.
$04 Calculated load value
Mode 42Pid$04 Adr$17
Calc. load value 1.9%
Display between 0% and 100%.
$05 Cylinder head temperature
Mode 42Pid$05 Adr$17
Temperature 93 °C
Display between - 40 °C and 215 °C.
$06 HO2S integrator, bank 1
Mode 42Pid$06 Adr$17
HO2S integrator B1 0.0%
Display: lean to -100% rich to 99.22%
$07 HO2S adaptation, bank 1
Mode 42Pid$07 Adr$17
HO2S adapt. B1 7.8%
Display: lean to -100% rich to 99.22%
$08 HO2S integrator, bank 2
Mode 42Pid$08 Adr$17
HO2S integrator B2 0.0%
Display: lean to - 100% rich to 99.22%
$09 HO2S adaptation, bank 2
Mode 42Pid$09 Adr$17
HO2S adapt. B2 7.8%
Display: lean to - 100% rich to 99.22%
$OC Engine speed
Mode 42Pid$0C Adr$17
Engine speed 778rpm
Display in rpm.
$OD Vehicle speed
Mode 42Pid$0D Adr$17
Vehicle speed 50 km/h