Test Point 13
TEST POINT 13
Left Door Secured But Not Locked
Fault Code 13
Procedure
1. Pull off plug I on the alarm control unit.
2. Disconnect plug connection X 11 (driver's side).
3. Check the line from the alarm control unit plug I, pin 30 to the door lock module for ground shorts.
Ohmmeter on alarm control unit plug I, pin 30 and ground.
Display: infinity
4. Check the driver's side door lock module switch contact.
Ohmmeter at plug connection X 11, pin A5 (sleeve side) and ground.
- Door locked
Display: infinity
- Door not locked
Display: < 5 ohms