Test Point 6
TEST POINT 6
Supply Voltage (5 Volt) Voltage Too High, Voltage Too Low
DTC 25
Diagnosis Conditions
- No control module fault stored.
Voltage Too High
1. Pull off connector C on the heating/air conditioning control.
2. Connect voltmeter to C 8 and ground. Switch on ignition.
Display: 0 Volts
If battery positive voltage is displayed, check wiring harness for pinching and chafing.
3. Push on connector C.
4. Connect voltmeter to C 8 and ground. Switch on ignition.
Display: 5 ± 0.5 Volts
If more than 5.5 Volts is displayed, replace the heating/air cond. control.
Voltage Too Low
1. Pull off connector C on the heating/air conditioning control.
2. Pull off all connectors on the valve drive motors.
3. Connect ohmmeter to connector C 8 and ground.
Display: infinity
If 0 - 5 ohms is displayed, check the wiring for pinching and chafing.
4. Check potentiometer in the drive motors.
- Temperature mixing valve:
Connect ohmmeter to pins 1 and 3.
Display: 4 - 5 kohms @ 23 °C
- Footwell / defrost valve:
Connect ohmmeter to pIns 1 and 3.
Display: 4 - 5 kohms @ 23 °C
- Central valve:
Connect ohmmeter to pins 1 and 3.
Display: 4 - 5 kohms @ 23 °C
- Outside air / recirculation valve:
Connect ohmmeter to pins 4 and 5.
Display: 4 - 5 kohms @ 23 °C