Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor Heating Ahead of TWC, Bank 1 - Open Circuit



P1115

13 Oxygen Sensor Heating Ahead of TWC, Bank 1 - Open Circuit

Diagnosis conditions
- Battery voltage between 9.5 V and 16 V
- Time elapsed after engine start-up greater than 10 seconds

Possible fault cause
- Open circuit

Affected terminals
II/19

Diagnosis/Troubleshooting

NOTE: Do not use contact spray on the connectors to oxygen sensor.


Part 1:




Part 2:






NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.