Operation CHARM: Car repair manuals for everyone.

External Bose Amplifier

8001 External BOSE amplifier

Supply voltage

Diagnostic conditions

- Ignition on
- PCM2/CDR23 ON

NOTE:
- Fault code 8003 is recorded in the PCM2 MMI if the operating buttons are actuated for one or more minutes.
- Deactivate the 'automatic traffic announcement' before performing the diagnosis on the PCM2. If this is not done, the diagnosis will abort.
- This fault is also detected and stored in the memory by other control modules.

Possible cause of fault
- Battery positive voltage too low 'less than 9 V for greater than 20 sec.'
- Battery positive voltage too high 'greater than 16 V for greater than 5 sec.'
- Fuse 'D9' faulty
- Check battery
- Generator regulator faulty
- Generator faulty

Affected pin
PCM2 plug A, pin 1, pin 2






Battery voltage too low

Diagnosis/troubleshooting







Battery voltage too high

Diagnosis/troubleshooting