Tiptronic System G100, G101, G102, G110
Fault Code 9Starter release (output)
Faults are detected in the wiring and in the output stage.
Diagnosis conditions
- Ignition on
Possible fault cause
- Short circuit to B+/ground or open circuit
- Tiptronic control module is faulty
Affected pins
Connector B: Pin 7
Diagnosis/troubleshooting