Oxygen Sensor After TWC, Bank 1 - Above Limit
P0138
Oxygen Sensor After TWC, Bank 1 - Above Limit
Diagnosis conditions
- Exhaust temperature between 250 °C and 750 °C
- Battery positive voltage greater than 9.5 V
- 200 seconds after start
Possible fault cause
- Short circuit to B+ in signal wire
Affected terminals
- II/17
Diagnosis/Troubleshooting
NOTE: Do not use contact spray on the connectors to oxygen sensors.
Work Instruction 1 - 3:
NOTE:
- Faults are recorded in these tests. Erase the fault memory.
- Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.
Oxygen sensors ahead of and after catalytic converter