Operation CHARM: Car repair manuals for everyone.

P1110

P1110

Oxygen Sensors Exchanged Ahead of TWC

Diagnosis conditions
- Engine at operating temperature
- Oxygen sensing system active

Possible fault cause
- Wiring harness

Affected terminals
II/15 and II/16

Diagnosis/Troubleshooting

NOTE: When the oxygen sensors are exchanged, then the oxygen sensors run contrary to the adaptation limitation.