Oxygen Sensor Heating After TWC, Bank 2 - Below Limi
P0057
Oxygen Sensor Heating After TWC, Bank 2 - Below Limit
Diagnosis conditions
- Engine running
Possible fault cause
- Short circuit to ground
Affected terminals
II/1
Diagnosis/Troubleshooting
NOTE: Do not use contact spray on the connectors to oxygen sensor.
Work Instruction 1 - 2:
NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.
Oxygen sensors ahead of and after catalytic converter
1 - Oxygen sensor ahead of catalytic converter
2 - Oxygen sensor after catalytic converter