Oxygen Sensor Heating After TWC, Bank 2 - Signal Implausible
P0161
Oxygen Sensor Heating After TWC, Bank 2 - Signal Implausible
Diagnosis conditions
- Exhaust temperature between 300 degree C and 600 degree C
- Battery voltage between 9.5 V and 16 V
Possible fault cause
- Corrosion in connector
- Oxygen sensor
Affected terminals
II/1
Diagnosis/Troubleshooting
NOTE: Do not use contact spray on the connectors to oxygen sensor.
Work Instruction 1 - 3:
NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter
Oxygen sensors ahead of and after catalytic converter
1 - Oxygen sensor ahead of catalytic converter
2 - Oxygen sensor after catalytic converter