Discharge Air Temperature Sensor / Switch: Service and Repair
Removing
1. Remove footwell bulkhead.
2. Unclip center console cover at the front and remove the foot well vent (3 screws).
3. Turn blower outlet sensor by -90 °- and pull it out.
4. Pull electrical plug connection off blower outlet sensor.
Installing
1. Position temperature sensor on the heating/air-conditioning unit housing and turn by 90 ° (tighten).
2. Engage electrical plug connection and route wire carefully.