8007 PCM2 MMI
8007 PCM2 - MMI
Open Circuit In Diagnosis Distribution Line
Diagnostic conditions
- Ignition on
- PCM2 ON
Possible cause of fault
- Diagnosis distribution line: short circuit to ground/ B+ or open circuit
- Optical waveguide damaged
- Optical waveguide broken
- Optical waveguide broken
- The receiving MOST control module is faulty
- PCM2 faulty.
NOTE:
The diagnosis distribution line is connected to the following MOST control modules:
- PCM2 as of model year 2003
- PCM2 Gateway
- PCM2 MMI
- PCM2 navigation (optional)
The diagnosis distribution fine and the MOST optical wave guide are connected to the following control modules:
- External amplifier (Harman or BOSE) (optional)
- CD changer (optional)
- Telephone/telematics (optional)
Affected pin
PCM2 plug, pin 4
Diagnosis/Troubleshooting