Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor Heating Ahead of TWC, Bank 1 - Open Circuit




P0030

Oxygen Sensor Heating Ahead of TWC, Bank 1 - Open Circuit

Diagnosis conditions
- Battery voltage between 9.5 V and 16 V
- Time elapsed after engine start-up greater than 10 seconds

Possible fault cause
- Open circuit

Affected terminals
II/19

Diagnosis/Troubleshooting

NOTE: Do not use contact spray on the connectors to oxygen sensor.


Work Instruction 1 - 4:






NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.

Oxygen sensors ahead of and after catalytic converter







1 - Oxygen sensor ahead of catalytic converter
2 - Oxygen sensor after catalytic converter