Oxygen Sensor Heating After TWC, Bank 1 - Open Circuit
P0036
Oxygen Sensor Heating After TWC, Bank 1 - Open Circuit
Diagnosis conditions
- Engine running
Possible fault cause
- Resistance of the oxygen sensor heating too great
- Open circuit
Affected terminals
II/7
Diagnosis/Troubleshooting
NOTE: Do not use contact spray on the connectors to oxygen sensor.
Work Instruction 1 - 3:
NOTE:
- Faults are recorded in this test, Refer to Erase the fault memory.
- Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.
Oxygen sensors ahead of and after catalytic converter
1 - Oxygen sensor ahead of catalytic converter
2 - Oxygen sensor after catalytic converter