P0136
P0136
12 Oxygen Sensor After TWC, Bank 1 - Signal Implausible
Diagnosis conditions
- Exhaust temperature between 250 °C and 750 °C
- Battery positive voltage greater than 9.5 V
- 200 seconds after start
- No secondary air
- No diagnosis of secondary air system
- No fuel tank ventilation
- No diagnosis of fuel tank ventilation system
- No faults in memory
Possible fault cause
- Short circuit to ground in signal wire
- Intercore short circuit
Affected terminals
- II/17
Diagnosis/Troubleshooting
NOTE: Do not use contact spray on the connectors to oxygen sensors.
Work Instruction 1 - 3:
NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.
Oxygen sensors ahead of and after catalytic converter