Activation Status Memory
Activation Status Memory
The alarm-triggering components that are in the non-active state during alarm system activation and that are therefore blocked for alarm triggering are stored in the activation status memory. The activation type also is saved. If the vehicle is secured, e.g. by remote control, and the oddments tray is open, this is indicated by the alarm system control memory by a brief horn signal. This status is stored in the activation status memory under "Oddments tray activation type: -by remote control-". This function can be used in troubleshooting, inasmuch as a faulty micro switch or faulty wire can be the cause for the horn signal. Reading out the activation status memory can help to track down the faulty alarm-triggering component, e.g. front lid, rear lid, oddments tray, etc.