84 Secondary Air Injection Pump - Open Circuit
P0418
84 Secondary air injection pump - open circuit
Diagnosis conditions
- Engine running
- Battery voltage greater than 7 V
Possible fault cause
- Wiring harness
- Relay faulty
- DME control module faulty
Affected terminals
Terminal III/11
Diagnosis/troubleshooting