CDR23
General Information On The Fault Memory
Fault code setting conditions
Fault codes can be set in several circumstances, e.g.
- battery disconnected
- plug connections disconnected
- power failure
In these circumstances, no fault is present in the system and the fault memory must be erased.
Fault memory Info key F8
In order to be able to assess the fault exactly, the fault memory Info key F8 must be pressed. This information should be saved using the Save key F4 and printed out. If a fault code is stored with "not present" status and no other problems are present, then the fault memory must be erased.
Fault type - Frequency counter/Temperature/Voltage; Speed
Fault type The display shows whether the fault is.
- not present
- present.
Frequency counter When a fault first occurs, a fault entry with the status present is set in the fault memory and the counter is simultaneously set to 50.
If a fault is present, the counter is incremented by one whenever the system is booted. The maximum count is 255.
The counter is decremented if the status fault no longer present is entered and the fault does not occur again when the system is booted. The entry in the fault memory is erased automatically when the counter reaches 0.
If the error occurs again when the counter is between 1 and 49, the counter is reset to 50.
Temperature: The value indicates the temperature (temperature sensor in the gateway) at the time the fault occurred. The temperature of the fibre optic transmitter is monitored: max 85 degrees C.
Voltage The value indicates the voltage at the time the fault occurred.
Vehicle speed: The value indicates the vehicle speed at the time the fault occurred.