8001 External BOSE Amplifier
8001 External BOSE Amplifier
Supply voltage
Diagnostic conditions
- Ignition on
- PCM2/CDR23 ON
NOTE:
- Fault code 8003 is recorded in the PCM2 MMI if the operating buttons are actuated for one or more minutes.
- Deactivate the automatic traffic announcement before performing the diagnosis on the PCM2. If this is not done, the diagnosis will abort.
- This fault is also detected and stored in the memory by other control modules.
Possible cause of fault
- Battery positive voltage too low < 9 V for > 20 sec.
- Battery positive voltage too high > 16 V for > 5 sec.
- Fuse D9 faulty
- Check battery
- Generator regulator faulty
- Generator faulty
Affected pin
PCM2 plug A, pin 1, pin 2
Battery voltage too low
Diagnosis/troubleshooting
Diagnosis/troubleshooting - Battery Voltage Too Low:
Battery voltage too high
Diagnosis/troubleshooting