Operation CHARM: Car repair manuals for everyone.

On-Board Diagnosis



Adaptive pressure limit values
1-2 shift, lower rpm range =-0.7 to +0.8 bar
1-2 shift, middle rpm range =-0.7 to +0.8 bar
1-2 shift, upper rpm range =-0.7 to +0.8 bar
2-3 shift, lower rpm range =-0.7 to +1.7 bar
2-3 shift, middle rpm range =-0.7 to +1.7 bar
2-3 shift, upper rpm range =-0.7 to +1.7 bar
3-4 shift, lower rpm range =-0.7 to +1.4 bar
3-4 shift, middle rpm range =-0 7 to +1.4 bar
3-4 shift, upper rpm range =-0.7 to +1.4 bar
4-5 shift, lower rpm range =-0.7 to +1.2 bar
4-5 shift, middle rpm range =-0.7 to +1.2 bar
4-5 shift, upper rpm range =-0.7 to +1.2 bar
5-4 shift, lower rpm range =-0.7 to +0.8 bar
5-4 shift, middle rpm range =-0.7 to +0.8 bar
5-4 shift, upper rpm range =-0.7 to +0.8 bar
2-1 shift, lower rpm range =-0.7 to +0.8 bar
2-1 shift, middle rpm range =-0.7 to +0.8 bar
2-1 shift, upper rpm range =-0.7 to +0.8 bar

NOTE: The adaptive pressure limits can be read out using the Porsche System Tester 2 (Menu/Actual values) and used for trouble-shooting.

Limits mean: no other value can be read out.

Maximum values does not mean that testing or repair work is necessary.

Carry out remedial work only in the event of complaints.