Fault Code 22
Fault Code 22
Passenger Compartment Monitoring Sensor, Short Circuit to Ground
Diagnostic conditions
- Alarm system primed
Possible cause of fault
- Short circuit to ground/open circuit in the wire between the alarm system control module and the passenger compartment monitoring sensor
Affected terminals
- Plug A, terminal 24
Diagnosis/troubleshooting
Work instructions