Removing and Installing
Removing
Removing The Magnetic Coupling:
1. Use a standard strap wrench to securely hold the pressure plate, and undo the fastening screw.
2. Screw a screw M8 into the thread of the pressure plate until the pressure plate can be removed manually.
3. Remove the spacer washers.
4. Use standard Seeger circlip ring pliers to remove the Seeger circlip ring. Manually remove the belt pulley.
5. Unscrew the cable of the magnetic coil from the compressor housing.
6. Remove the Seeger circlip ring.
7. Remove the magnetic coil from the compressor housing.
Installing
Installing The Magnetic Coupling:
1. Place the magnetic coil on the compressor housing (the locking pin must engage in the locking hole).
2. Install the Seeger circlip ring. The -slanted surface- of the Seeger circlip ring faces upwards (to the fastening screw).
3. Tighten the pressure plate fastening screw.
Tightening torque 14 Nm (10 ft. lbs.)