Ambient Temperature Sensor / Switch HVAC: Service and Repair
Removing
NOTE: Removing and installing outside temperature sensor on the installed heating/air-conditioning unit.
1. Remove footwell bulkhead and right air guide.
2. Remove drive motor for fresh-air/recirculation valve.
3. Pull off electrical plug connection on the outside temperature sensor.
4. Turn temperature sensor by -90 °- and pull it out.
Installing
1. Place temperature sensor on the intake duct and turn by 90 ° (tighten).
2. Engage electrical plug connection and route wire carefully.
3. Install drive motor for fresh-air/recirculation valve and perform a function test.