35, Multi-Function Switch
P0706
35, Multi-function switch
Diagnosis conditions
- Ignition on
- Selector lever in a position
Possible fault cause
- Short circuit to ground/B+/mutual short circuit or open circuit between control module and multi-function switch
- Multi-function switch is faulty
- Tiptronic control module is faulty
Affected pins
Pin 8, pin 9, pin 36, pin 37, pin 25
Diagnosis/troubleshooting