Installing the Electrohydraulic Control Unit
Installing the electrohydraulic control unitInstall in reverse order, observing the following points:
1. Place selector lever in position -P- and place the control unit carefully in position. The selector valve must engage in the driver of the notched plate.
2. First tighten screws for the control unit hand tight. Then tighten.
Tightening torque: 8 Nm (6 ft. lbs.).
3. Replace gasket for ATF pan.
4. Insert the plug connection with new sealing rings in the correct position and tighten the fastening screw.
Tightening torque: 2.5 Nm (2 ft. lbs.).
5. Push the plug into the plug connection and lock by turning it to the right.
6. Install the holder for water hoses. It is essential that the centering pin engages in the holder bore. Tighten the fastening screw.
Tightening torque: 10 Nm (7.5 ft. lbs.).
7. Install the coolant hoses with hose holders in the correct position.
8. Push vacuum pipe onto switch-over valve.
9. Fill in ATF. -> Go to Page 216 'Checking and topping up ATF (as of model year 2002)'