Operation CHARM: Car repair manuals for everyone.

Fault Code 11





Fault Code 11

Voltage Failure During Alarm Output

Diagnostic conditions
- Voltage failure during alarm triggering

Possible cause of fault
- Low battery positive voltage
- Open circuit in wiring to the control module

Affected terminals
- Plug B, terminal 7

Diagnosis/troubleshooting




Work instructions