Fault Code 36
Fault Code 36
Passenger Compartment Monitoring Sensor, Short Circuit to B+ or Faulty
Diagnostic conditions
- Alarm system activated
Possible cause of fault
- Short circuit to voltage in the wiring between the alarm system control module and the passenger compartment monitoring sensor
- Passenger compartment monitoring sensor faulty
Affected terminals
- Plug A, terminals 8 and 24
Diagnosis/troubleshooting
Work instructions