Fault Code 29
Fault Code 29
Outside air/recirculation Air Motor - No reaction to activation, signal unclear
Diagnostic Conditions:
- Ignition on
NOTE:
- No control module fault stored
- No fault with supply voltage (5 V)
Possible cause of fault:
- Short circuit to voltage/ground or open circuit in the wiring between the air-conditioning system regulator and the outside air/recirculation air
- Servo motor for outside air/recirculation air faulty or flap does not open/close smoothly,
Affected Terminals:
- Plug B, terminals 9, 17 and 20
- Plug D, terminals 5 and 13
Diagnosis/troubleshooting