8009 PCM2 MMI
8009 PCM2 - MMI
Optical/Electrical Open Circuit In MOST Distribution Line
Diagnostic conditions
- Ignition on
- PCM2 ON
Possible cause of fault
- An optical (optical waveguide) or electrical (PCM2 internal) open circuit in the ring
- MOST switch in production mode
- MOST switch incorrectly coded
- An optically/electrically faulty MOST control module is connected to the MOST
NOTE:
The MOST optical wave guide is connected to the following control modules:
- PCM2 as of model year 2003
- CD changer
- Amplifier
- Telephone/telematics
Affected pins
- none
Diagnosis/Troubleshooting