Fault Code 19
Fault Code 19
Lumbar Pressure Sensor - Short Circuit
Diagnostic conditions
- Ignition on
- Switch for memory seat adjustment actuated
Possible cause of fault
- Short circuit to B +/ground or open circuit in supply lead of pressure sensor
- Pressure sensor faulty
- Control module faulty
Affected terminals
- Plug 9, pins 1, 2 and 3
Diagnosis/troubleshooting
Work instructions 1 - 4