P0713
P0713
Transmission Oil Temperature - Above Limit
Diagnosis conditions
- Idle speed
Possible fault cause
- Temperature sensor faulty
- Wiring harness
- DME control module faulty
Affected terminals
Terminal II/23 and IV/11
Resistance values
60 °C 2.8 - 3.5 kOhms
90 °C 1.0 - 1.3 kOhms
120 °C 0.4 - 0.6 kOhms