Operation CHARM: Car repair manuals for everyone.

O2 Sensing Adaptation, Lower Load Range, Bank 1 - Below Limit




P1126

356 Oxygen Sensing Adaptation, Lower Load Range, Bank 1 - Below Limit

Diagnosis conditions
- Oxygen sensing system active
- lime elapsed after engine start-up: 250 to 350 seconds (USA)
- Time elapsed after engine start-up: 302 to 402 seconds (RoW)
- Engine temperature greater than 60 °C

Possible fault cause
- Incorrect signal from MAF sensor
- Fuel pressure too high
- Fuel injector leaking

Affected terminals
- (none)

Diagnosis/Troubleshooting

NOTE:
- If DTC P0445 (EVAP canister purge valve-short to ground) is stored in the memory, correct this fault first. An open EVAP canister purge valve can lead to the lean threshold being reached.
- If the fuel tank reserve light is switched on, no fault is entered.

Work Instruction 1 - 4: