P1140
P1140
Throttle Position Sensor 2 - Above Limit
Diagnosis conditions
- Engine running
Possible fault cause
- Short circuit in wiring
- Throttle position sensor faulty
- DME control module faulty
Affected terminals
Terminal I/7, I/9, III/8, III/10 and III/25
Diagnosis/Troubleshooting
Part 1:
Figure 1:
Figure 2:
Part 2:
Disconnection point throttle part:
NOTE: The wires to the throttle part are routed via connector X 59/2.