P1671



P1671

DME relay/control module faulty (computer monitoring: reset) - signal implausible

Diagnosis conditions
- Ignition on

Possible fault cause
- Undervoltage
- DME relay faulty
- DME control module faulty

This fault may be entered if the control module has been operated with undervoltage.

Affected terminals
I/1 and I/8

Diagnosis/troubleshooting

NOTE: If no fault is present, erase the fault memory.