P1671
P1671
DME relay/control module faulty (computer monitoring: reset) - signal implausible
Diagnosis conditions
- Ignition on
Possible fault cause
- Undervoltage
- DME relay faulty
- DME control module faulty
This fault may be entered if the control module has been operated with undervoltage.
Affected terminals
I/1 and I/8
Diagnosis/troubleshooting
NOTE: If no fault is present, erase the fault memory.