8003 PCM2 - MMI
8003 PCM2 - MMI
Operating buttons are jammed
Diagnostic conditions
- Ignition on.
- PCM2 on.
- Manual actuation
NOTE: Actuating the operating buttons for 1 Min. results in a fault code 8003 being recorded.
Possible cause of fault
- Internal short circuit
Affected pins
Diagnosis/troubleshooting