Fault Code 100
Fault Code 100
Solenoid 1 activation
NOTE:
- Fault code 100 can no longer be deleted.
- Once the cause of the fault has been identified and rectified, the roll-over protection control module must be replaced.
Diagnostic conditions
- Ignition on
Possible cause of fault
- Short circuit to B+/ground/between wires or open circuit in the wires between roll-over protection control module and solenoid 1 at triggering stage
- Solenoid 1 faulty
- Roll-over protection control module faulty
Affected pins
Pin 4 and pin 5
Diagnosis/troubleshooting
DANGER:
- Danger of personal injury by remaining within the functioning range of the roll-over bars.
- Danger of personal injury by placing objects within the functioning range of the roll-over bars.
The roll-over bars may be triggered accidentally or intentionally during the diagnosis/troubleshooting even if the battery was clamped beforehand.
- Before starting the diagnosis/troubleshooting, open the convertible top completely, remove the cover caps and, if necessary, the hardtop from the vehicle.
- Ensure that body parts are kept away from the functioning range of the roll-over bars.
- Ensure that objects are kept away from the functioning range of the roll-over bars.
- During all work and analysis/troubleshooting on the roll-over protection system, roll-over protection must be actuated beforehand and only retracted again when all work is complete.