Fault Code 40
Alarm system I32; 148
Fault code 40
Signal converter coil fault
Diagnostic conditions
- Ignition on
Possible cause of fault
- Short circuit to voltage/ground or open circuit in the wiring between the transponder coil and the signal converter
Affected terminals
Plug on signal converter, pins 1 and 2
Diagnosis/troubleshooting