Test Point 19
TEST POINT 19
Status Line, Signal Converter, Positive Short
Fault Code 19
Fault Effect: No engine start possible
Procedure
1. Pull off plug I on the alarm control unit.
2. Pull off the plug on the signal converter for the transponder.
3. Voltmeter at plug I alarm control unit pin 12 and ground. Switch on the ignition.
Display: 0 Volts
If the battery voltage is displayed, check the wiring harness for pinches and chafing damage.