Test Point 9
TEST POINT 9
Button, Central Locking System Open/closed, Positive Short
Fault Code 09
Fault Effect: No central locking or unlocking possible
Procedure
1. Pull off plug I at the alarm control unit.
2. Check the central locking button.
Voltmeter at plug I, pin 29 and ground.
- Central locking button not actuated.
Display: 0 V
- Central locking button actuated towards "Closed".
Display: Battery voltage
Voltmeter at plug I, pin 10 and ground.
- Central locking button not actuated.
Display: 0 V
- Central locking button actuated towards "Open".
Display: Battery voltage
3. Disconnect the plug connection on the central locking button.
4. Check the lines from the alarm control unit to the central locking button for positive shorts.
- Voltmeter at plug I, pin 29 and ground.
Display: 0 V
- Voltmeter at plug I, pin 10 and ground.
Display: 0 V